Basic wiring · one door

Four low-voltage wires per door

As installed and tested with a Mercury panel. The second, third and fourth doors on the same I/O device repeat the pattern on inputs and relays 2–4.

Wiring for one door: 12–24 VDC supply, Mercury aux relay common fed from the supply, normally open contact to the I/O device input 1; I/O device relay 1 and common to Mercury alarm input 1 12–24 VDC supply fused · or PoE-powered models Access control panel Mercury · use your board's labels AUX RELAY (access granted) C NO ALARM INPUT (tailgate) IN1 + IN1 − I/O-to-network device voltage inputs · relays 24 VDC / 1 A Power + Input 1 + Relay 1 Relay com counts badges tailgate pulse Power − to supply − ① supply + → relay C (signal voltage) ② relay NO → Input 1 (badge pulse) ③ Relay 1 → IN1+ (tailgate) ④ Relay com → IN1− +

Use a spare AUX relay

Program it to pulse on "access granted" for that door. Not the lock or strike relay, which also fires on request-to-exit and held-open.

Dry contacts both ways

Every signal crosses a relay contact, so the panel and the I/O device stay electrically separate. Their grounds don't need to be joined.

Alarm input as normal

Set the panel input as a normally-open alarm point, with the end-of-line resistors your input configuration uses.

Life safety

Built to stay out of the life-safety path

PassMatch only watches and reports. It never decides whether a door locks or unlocks, and it is wired so it can't.

Free egress unchanged

Exit hardware, request-to-exit and fire-alarm release are not connected to it. People leave exactly as before.

Fails quiet

If the PC, camera, I/O device or network stops, doors and access control keep working normally. You only lose the tailgate alarm, and the monitor reports the device as down.

Low voltage, signal only

12–24 VDC signal circuits through relay contacts rated 1 A. No mains wiring at the door.

Privacy by design

No video leaves the camera, and nothing is stored but counts and times.

Door circuitConnected?
Lock / strike / maglock powerNo
Request-to-exit (REX)No
Fire alarm door releaseNo
Panic / exit hardwareNo
Door position contactNo
Spare AUX relay (listen only)Yes
Spare alarm input (report only)Yes

Install by a qualified installer to the panel maker's instructions, local codes and the authority having jurisdiction. Use spare panel points only.

What's needed

Per site

1 / door
Axis camera with Object Analytics

Overhead or angled at the door, "crossline counting" scenario. Tested with the Axis P3288-LVE.

1 / closet
PassMatch unit

Raspberry Pi 5 with stackable relay boards: each board has 4 dry-contact inputs and 4 relays, so 2 boards cover 8 doors. Or an I/O-to-network device per 4 doors.

2 / door
Spare panel points

One auxiliary relay (access granted) and one alarm input (tailgate).

1
Mother (for 2 or more units)

Any always-on Windows PC, or its own Raspberry Pi with a screen. No internet connection needed.

opt.
Room sensors

A water probe and a temperature and humidity sensor per room, on the unit's spare input.

—
12–24 VDC supply, PoE switch, cabling

Standard low-voltage installation materials.

Specifications

Light on the PC

Alarm timeUnder 1 second from the person crossing
DoorsUp to about 8 per unit, any number of units per mother
Delay per doorSet per door, e.g. 5–15 s
CPUUnder 1% of one core at 100 busy doors
MemoryAbout 35–40 MB
NetworkAbout 1 KB per badge or person
InternetNone
Event historyKept 90 days by default (adjustable)
Ports (local only)8080 I/O devices · 1883 cameras · 8081 web page